≤480s Benzene Analysis RS232 RS485 Output Advanced Voc System for Measuring Total Hydrocarbons and Methane Levels
China JiangsuWuxi Yongan Electronic Technology Co., Ltd.
US$21300.00 - 21980.00
MOQ1 Pieces
Product profile
- Target Analytes
- Total Hydrocarbons (Thc), Methane (CH4), Non-Metha
- Measuring Range
- 0-100 / 200 / 500 / 5000 Mg/M³ (Range Extendable)
- Auxiliary Parameters
- Temperature; Pressure; Flow Velocity; Humidity; Ox
- Detection Limit
- ≤ 0.05 Ppm (for Nmhc)
- Repeatability
- Rsd ≤ 2%
- Analysis Time
- ≤ 2 Min (for CH4 & Nmhc); Benzene Series ≤ 480 S;
- Indication Error
- ≤ ±2% of F.S.
- Zero Drift
- ≤ ±2% F.S. / 24 H
- Span Drift
- ≤ ±2% F.S. / 24 H
- Response Time
- ≤ 300 S (for Nmhc)
- Accuracy
- ≤ ±10%
- Calibration Cycle
- Weekly
- Output
- RS232 / RS485
- Environmental Conditions
- Operating: 5-45 °C, <90% Rh (Non-Condensing); Stor
- Gas Supply
- Hydrogen (H2) and Zero-Grade Air
Company profile
Wuxi Yongan Electronic Technology Co., Ltd.
无锡市永安电子科技有限公司China JiangsuWuxi, Jiangsu, China- CertifiedVerified Supplier
- CertifiedTrade Assurance
- Business Type: Combined
- Established: 2011
- Employees: 41
- Plant Area: 1527.87m²
- Avg. Response Time: ≤ 0.35h
- Certification: ISO9001:2015 certificate,ISO45001:2018 certificate,ISO14001
- System Certification: ISO9001:2015 certificate,ISO14001:2015 certificate
Main Products
- Combustibl/Toxic Gas Leak Alarm Control System
- Zirconia Oxygen Analyzer
- Cems Flue Gas Online Monitoring System
- Temperature Transmitter
- Pressure Transmitter
- Fixed Combustible/Toxic Gas Detector
- Pipeline Spark Alarm and Control System
- Flow Meter
- Dust Detector
- Temperature and Humidity Transmitter
Main Markets
South America,Africa,Southeast Asia/ Mideast,East Asia(Japan/ South Korea),Domestic,Europe,North America