Source Superfine Dry Powder Fire Extinguisher for Warehouses, Workshops, and Vehicles
Compare 30 listings for the superfine dry powder fire extinguisher, featuring models with ammonium phosphate or sodium bicarbonate agents. Buyers can review certifications like CE and CCCF, sizes ranging from 1kg to 12kg, and operating temperatures between -50°C and +110°C.
Key considerations
Products List
Comprehensive Sourcing Guide
Strategic Sourcing Guide for Superfine Dry Powder Fire Extinguishers
Understanding Technical Specifications and Performance Metrics
When sourcing superfine dry powder fire extinguishers, buyers must first distinguish between general dry powder agents and the specific "superfine" classification observed in the market. The core differentiator lies in particle size and flow dynamics. The provided product data explicitly identifies "Superfine Powder" as a distinct variant, often associated with specific model types such as the MFZ series. This classification suggests a higher surface area-to-volume ratio, which theoretically enhances the extinguishing efficiency by smothering the fire more rapidly and preventing re-ignition.
The technical profile of these units varies significantly based on the intended fire class. While the market data indicates a "Class C Fires" object for certain superfine models, other entries in the dataset reference "Class A Fires" and "Class D Fires." This discrepancy highlights the critical need for buyers to verify the specific agent composition against their hazard assessment. For instance, one dataset entry lists "Ammonium Phosphate" as the main content, while another specifies "Sodium Bicarbonate Powder." These are chemically distinct agents suited for different fire scenarios. Ammonium phosphate is typically associated with ABC-rated extinguishers capable of handling ordinary combustibles, flammable liquids, and electrical fires, whereas sodium bicarbonate is often used for Class B and C fires.
The physical construction and operational parameters are equally vital. The observed units feature a "Spray Painted Shell" made of "Steel," ensuring durability in industrial environments. The operating temperature range is documented as -50 °C to +110 °C, a wide spectrum that accommodates extreme storage conditions. However, the surface temperature of the extinguisher during operation or storage is noted to be ≤ 150 °C, a factor that must be considered for placement near heat-sensitive materials. The discharge time is recorded between 15 to 30 seconds, with a spray time of ≤ 10 seconds, indicating a rapid application rate. The effective range varies, with some models citing a 9-meter reach, while others are designed for close-protection scenarios with a 1kg capacity.
| Feature Category | Observed Specification | Verification Requirement |
|---|---|---|
| Powder Type | Superfine Powder, Ordinary Dry Powder | Confirm particle size distribution and agent compatibility. |
| Fire Class | Class A, Class C, Class D | Match specific fire risk to the extinguisher rating. |
| Main Content | Ammonium Phosphate, Sodium Bicarbonate | Verify chemical composition against hazard type. |
| Capacity | 1kg to 12kg (Sizes: 3, 4, 5, 6, 7, 8, 10, 12kg) | Select size based on room volume and fire load. |
| Working Pressure | 1.2MPa | Ensure pressure rating matches cylinder design standards. |
| Discharge Time | 15-30s | Validate flow rate for the specific application area. |
Compliance and Certification Verification Protocols
Navigating the certification landscape for fire safety equipment requires rigorous due diligence. The supplied data reveals a mix of certifications including CE, CCC, CCCF, and ISO9001. It is imperative for buyers to understand that these certifications are not universal; they apply to specific models and manufacturing batches. For example, the "Ammonium Phosphate Powder Model" is explicitly linked to CE, CCC, and GB8013-CCCF standards. Conversely, other entries list only CE or a combination of CE and CCC.
The presence of the CCCF (China Compulsory Fire Product Certification) is particularly significant for products intended for the Chinese market or those manufactured in China. The data indicates a "Place of Origin" of Jiangxi, China, and another entry points to Shenzhen, China. Buyers must ensure that the specific model they are procuring carries the valid CCCF mark if it is destined for use in jurisdictions requiring this certification. Relying on a general "ISO9001" claim is insufficient for fire safety compliance, as this certifies the quality management system of the manufacturer rather than the safety performance of the extinguisher itself.
Furthermore, the dataset mentions a "Validity" of 5 years and a "Retirement Life" of 10 years. These figures are critical for long-term procurement planning but must be cross-referenced with local regulations. The "Shelf Life" is noted as 2 years for the powder agent, which implies that the chemical composition may degrade or settle over time, necessitating regular maintenance or replacement schedules. Buyers should not assume that a 10-year retirement life applies to the powder itself; rather, it likely refers to the structural integrity of the steel cylinder. Verification of the specific certification status for the ordered model number is essential, as the dataset shows variations even within the same product line.
Cost Drivers and Pricing Structure Analysis
The pricing for superfine dry powder fire extinguishers in the observed market spans a wide range, from $0.86 to $130 USD. This disparity is not indicative of a single product category but rather reflects the vast differences in capacity, certification level, and customization options. The minimum order quantity (MOQ) ranges from 1 to 1000 units, suggesting that pricing is highly volume-dependent. A unit priced at $0.86 likely represents a bulk industrial component or a very small, specialized unit, whereas the $130 figure likely corresponds to a fully certified, larger capacity unit (e.g., 12kg) with comprehensive documentation.
Several factors drive the cost structure. First, the "Customization" attribute is available, allowing buyers to request specific colors, branding, or capacity modifications. Customization invariably increases the unit cost and may extend lead times. Second, the material composition plays a role; while the standard material is "Steel" with a "Spray Painted Shell," specialized coatings or thicker gauge steel for higher pressure ratings (1.2MPa) will increase manufacturing costs. Third, the certification costs are embedded in the price. Models with CCCF and CE certifications undergo more rigorous testing and quality control than those with only basic ISO9001 backing.
Buyers must also consider the "Power Source" type. The data lists both "Pressure Fire Extinguisher" and "Chemical Reaction Fire Extinguisher." The latter typically involves a more complex internal mechanism to generate the propellant, which can influence the price. Additionally, the "Item Weight" of 10g mentioned in the data seems anomalous for a full extinguisher and may refer to a component or a specific miniature unit, further complicating direct price comparisons. To manage costs effectively, buyers should prioritize the exact capacity and certification required for their specific site, avoiding over-specification while ensuring compliance.
Typical Applications and Hazard Assessment
The application of superfine dry powder extinguishers is dictated by the fire class they are rated to suppress. The dataset presents a complex picture of fire classes, listing "Class A Fires" (ordinary combustibles), "Class C Fires" (flammable gases/electrical), and "Class D Fires" (combustible metals). This indicates that "superfine dry powder" is a broad term that can apply to different chemical agents depending on the formulation.
For facilities handling electrical equipment, the "Class C" designation is critical. The "Sodium Bicarbonate Powder" model is often cited for this purpose, as it is non-conductive and effective on energized electrical fires. However, if the facility also deals with wood, paper, or textiles, the "Ammonium Phosphate" formulation, which targets "Class A Fires," would be necessary. The "Class D" reference suggests the existence of specialized agents for metal fires, which require specific superfine powders to smother the intense heat and prevent reaction with water or other agents.
The "Effective Range" of 9 meters makes these units suitable for medium-sized rooms or industrial corridors where the fire source might be at a distance. However, the "Discharge Time" of 15-30 seconds suggests that for large fires, a single unit may not be sufficient, necessitating a strategy of multiple units or a larger capacity model (e.g., 12kg). The "Humidity" tolerance of ≤ 95% makes these units suitable for humid environments, such as coastal industrial zones or unconditioned warehouses, provided the cylinder remains dry.
| Application Scenario | Recommended Agent | Key Specification to Verify |
|---|---|---|
| Electrical Panels | Sodium Bicarbonate (Class C) | Non-conductive rating, CE/CCCF certification. |
| Wood/Paper Storage | Ammonium Phosphate (Class A) | Class A rating, 2-year shelf life. |
| Metal Processing | Specialized Class D Agent | Specific Class D certification, superfine particle size. |
| High Humidity Zones | Any Dry Powder | ≤ 95% Humidity tolerance, corrosion-resistant shell. |
Supplier Evaluation and Manufacturing Origin
The supply chain for these extinguishers is concentrated in China, with specific mentions of Jiangxi and Shenzhen as places of origin. When evaluating suppliers, buyers should verify the specific manufacturing location, as quality control standards can vary between regions. The dataset indicates that "Customization" is available, which implies a level of flexibility in the manufacturing process. However, this flexibility must be balanced against the risk of inconsistent quality if the supplier lacks robust process controls.
Buyers should request proof of the "ISO9001" certification for the manufacturing facility, not just the product. This ensures that the production process adheres to international quality management standards. Additionally, the "Certificate" field in the data lists "CE" and "CCC," but buyers must confirm that the specific batch they are purchasing carries these marks. The "Product Model" (e.g., FZX-ACT, MFZ, ABC) should be clearly defined in the purchase order to avoid receiving a generic unit that does not meet the specific fire class requirements.
The "Product Packing" is listed as "Box/Carton" or simply "Carton." For international shipping, the packaging must be robust enough to prevent damage to the steel cylinder during transit, especially given the "Work Pressure" of 1.2MPa. Suppliers should be asked to provide details on their packaging standards to ensure the extinguishers arrive in operational condition. The "Lead Time" is not explicitly provided in the data, but the "Customization" attribute suggests that custom orders may require longer production windows compared to standard stock items.
Quality Control and Long-Term Procurement Strategy
Ensuring the long-term reliability of superfine dry powder fire extinguishers requires a proactive quality control strategy. The "Shelf Life" of 2 years for the powder is a critical constraint. Buyers must implement a rotation schedule or a maintenance program that checks the powder condition before the 2-year mark. The "Retirement Life" of 10 years for the cylinder provides a longer horizon for asset management, but the internal components, such as the pressure gauge and seal, must be inspected regularly.
The "Surface Temperature" limit of ≤ 150 °C is a safety parameter that should be monitored during storage. Extinguishers stored near heat sources or in direct sunlight may exceed this limit, potentially compromising the internal pressure or the integrity of the powder. Buyers should specify storage conditions in their procurement contracts, ensuring that the supplier's recommended storage environment is followed.
For long-term procurement, buyers should consider the "Validity" of 5 years. This likely refers to the period during which the extinguisher is guaranteed to function without major intervention. However, the "Chemical Reaction Fire Extinguisher" type listed in the data may have different maintenance requirements compared to the "Pressure Fire Extinguisher" type. Understanding the specific maintenance needs of the chosen model is essential for total cost of ownership calculations.
Finally, the "Item Weight" of 10g mentioned in the data is an outlier that warrants clarification. If this refers to the weight of the powder agent in a specific miniature unit, it highlights the importance of verifying the exact specifications of the ordered model. Buyers should always request a detailed technical data sheet (TDS) that confirms the weight, capacity, and agent type before finalizing a purchase. By adhering to these verification steps, buyers can mitigate the risks associated with the varied specifications observed in the market and ensure the procurement of high-quality, compliant fire safety equipment.
FAQs
What certifications are available for superfine dry powder fire extinguishers?
Certifications such as CE, CCC, and CCCF are available for specific models like the Ammonium Phosphate Powder. Buyers must verify that the exact model number carries the required mark for their jurisdiction, as ISO9001 only certifies the manufacturer's quality system rather than the product safety performance.
Which fire classes can superfine dry powder extinguishers handle?
These units are rated for Class A, Class C, and Class D fires depending on the specific agent used. Ammonium Phosphate targets Class A combustibles, while Sodium Bicarbonate is suitable for Class C electrical fires, so users must match the chemical composition to their specific hazard assessment.
How long is the shelf life and validity of the extinguisher?
The powder agent has a shelf life of 2 years, while the extinguisher unit itself has a validity of 5 years. The total retirement life for the steel cylinder is 10 years, but regular maintenance is required because the chemical composition may degrade or settle over time.
Can buyers request customization for color or capacity?
Customization is available for color, branding, and capacity modifications, but this will increase the unit cost and may extend lead times. Buyers should prioritize the exact capacity and certification required for their site to avoid over-specification while ensuring compliance with local safety regulations.
What is the operating temperature range for these extinguishers?
The units operate effectively within a temperature range of -50 °C to +110 °C, accommodating extreme storage conditions. The surface temperature during operation or storage is noted to be less than or equal to 150 °C, which must be considered for placement near heat-sensitive materials.
What is the discharge time and effective range of the unit?
The discharge time is recorded between 15 to 30 seconds with a spray time of less than 10 seconds. Some models offer an effective range of up to 9 meters, making them suitable for medium-sized rooms, though larger fires may require multiple units or a higher capacity model.
Which materials are used for the extinguisher shell construction?
The shell is constructed from steel with a spray-painted finish to ensure durability in industrial environments. This material choice supports the working pressure of 1.2MPa and ensures the cylinder remains robust during transit and long-term storage in various humidity conditions up to 95 percent.