Source Vacuum Drying Table Top Autoclave for Labs, Clinics, Hospitals

Compare 30 vacuum drying table top autoclave units from verified Chinese manufacturers. These pressure steam sterilization equipments feature automatic operation, LCD displays, and customizable drying procedures for medical and laboratory applications; compare the available evidence and request quotations based on your requirements.

Key considerations

Products List

Comprehensive Sourcing Guide

Vacuum Drying Table Top Autoclave Sourcing Guide

The vacuum drying table top autoclave represents a specialized category of pressure steam sterilization equipment designed for precise medical and laboratory applications. Based on observed market listings, these units typically feature automatic operation with LCD displays and utilize stainless steel chambers to ensure durability and hygiene. Buyers should note that while the core function remains consistent, specific models like the HP-AC2N and HP-HAC150 offer varying capacities, ranging from compact 12L units to larger configurations, necessitating careful selection based on facility volume requirements.

Procurement decisions must account for the specific drying procedures and temperature ranges required for the intended sterilization cycle. The observed data indicates a working temperature range of 105 to 136 degrees Celsius, with some models supporting dual temperatures of 121 and 134 degrees for different material compatibility. Since these devices are classified under imaging diagnostic equipment and serve middle-aged and old patient demographics, verifying the ambient temperature tolerance of 5 to 40 degrees is critical for ensuring stable operation in diverse clinical environments without compromising the heating dry process.

Product Scope and Observed Listing Signals

When evaluating product listings, buyers must distinguish between different model series such as the HP-AC12B and NB-T24J, as they present distinct electrical and capacity profiles. The market shows a wide price range from 250 to 50,000 USD, reflecting variations in chamber volume, power supply requirements, and advanced features like sterilization information recording. It is essential to verify the specific water capacity per cycle, which can be as low as 0.3L for smaller units or significantly higher for industrial-grade models, to ensure the equipment matches the daily throughput needs of the facility.

Customization availability is a key signal in the current market, allowing buyers to tailor specific attributes to their operational workflows. Listings frequently highlight features such as water separation capabilities and ultra-high temperature alarms, which are vital for safety and process integrity. However, the observed minimum order quantities vary between 1 and 5 units, suggesting that while small clinics can purchase single units, larger procurement strategies might benefit from bundling orders to optimize logistics and potentially negotiate better terms for the regular or wooden packaging options provided.

Technical Specifications to Verify

Technical verification begins with the electrical tension and power supply requirements, which vary significantly between models ranging from 220V to 380V at 50Hz. Buyers must confirm that their facility's power infrastructure can support the specific voltage, such as the 380V requirement for the HP-AC12B, to prevent operational failures or safety hazards. Additionally, the power consumption, noted as 1.5kw for certain table-top models, should be factored into energy budgeting and electrical load calculations to ensure the autoclave integrates seamlessly with existing utility systems without requiring costly upgrades.

Pressure and temperature precision are critical parameters that define the sterilization efficacy and safety of the equipment. The observed maximum working pressures range from 0.1 bar to 0.23 MPa, with temperature precision often specified at 0.1 degree increments. Buyers should verify the adjustment range, typically 105 to 126 degrees Celsius, and ensure the device includes robust alarms for temperature deviations. Confirming the chamber volume, such as the 24L capacity with specific dimensions, is also necessary to validate that the physical footprint fits the designated laboratory or medical space while accommodating the required load volume.

Compliance and Safety Documentation

Compliance with international standards is non-negotiable for medical sterilization equipment, and buyers must verify that the product holds valid certifications such as CE, SGS, and ISO13485. The observed listings indicate that suppliers often provide ISOSGS and CE certifications, which are essential for market entry and regulatory approval in various regions. It is imperative to request current, verifiable documentation for these standards rather than relying on general claims, ensuring that the specific model being purchased has undergone the necessary testing and quality assurance processes required for medical use.

Safety features must be explicitly documented to protect operators and ensure the integrity of the sterilization cycle. The presence of ultra-high temperature alarms and pressure monitoring systems, with precision levels like 0.1kpa, serves as a primary defense against equipment malfunction. Buyers should confirm that the device includes comprehensive sterilization information recording and printing capabilities, which provide an audit trail for regulatory compliance. Verifying that the equipment meets the classification for imaging diagnostic equipment and functions safely within the specified ambient temperature range is crucial for maintaining a safe clinical environment.

Cost Drivers and Commercial Terms

The total cost of ownership is influenced by several factors beyond the initial purchase price, including the complexity of the power supply and the specific capacity of the unit. Models requiring 380V power or offering larger capacities like 150L, 200L, or 300L typically command higher prices, reflecting the increased material and engineering costs. Buyers should analyze the competitive pricing structure observed in the market, noting that while some listings advertise competitive rates, the final cost must be weighed against the long-term reliability and the specific technical specifications required for the intended application.

Commercial terms such as minimum order quantities and packaging requirements significantly impact the procurement strategy and logistics planning. With MOQs ranging from 1 to 5 units, buyers have flexibility but must consider the shipping implications of different packaging types, such as regular packing versus wooden packages for larger or more fragile units. The origin of the product, specifically Zhengzhou, China, and the global export markets served by suppliers, should be factored into lead time estimates and shipping cost calculations. Understanding these variables helps in negotiating favorable terms that align with the organization's budget and timeline constraints.

Supplier Qualification and Quality Control

Supplier qualification requires a rigorous assessment of their manufacturing capabilities and adherence to quality management systems. Buyers should prioritize suppliers who demonstrate a clear track record of producing pressure steam sterilization equipment with documented customization options and consistent adherence to standards like ISO13485. The ability to provide detailed product specifications, including material composition such as stainless steel and precise dimensional data, is a strong indicator of a supplier's technical competence and commitment to quality control throughout the production process.

Quality control protocols must extend beyond the final inspection to include the entire manufacturing lifecycle. Buyers should verify that the supplier implements strict checks on critical components like the LCD display, pressure sensors, and heating elements to ensure they meet the specified working temperatures and pressures. Requesting evidence of the water separation functionality and the accuracy of the temperature adjustment mechanisms is essential. A qualified supplier will provide transparent information regarding their production standards and be willing to share test results or quality assurance reports that validate the performance of the autoclave before shipment.

Long-Term Procurement Checks

Long-term procurement success depends on establishing a reliable supply chain for spare parts and ongoing technical support. Buyers should confirm the availability of replacement components such as seals, sensors, and control boards, which are critical for maintaining the operational efficiency of the autoclave over its lifespan. The specific model number, such as HP-HAC150 or NB-T24J, should be used to ensure compatibility when ordering parts, preventing downtime that could disrupt critical sterilization workflows in medical or laboratory settings.

Performance monitoring and periodic recalibration are essential to maintain the accuracy of the sterilization cycle and ensure continued compliance with safety standards. Buyers must implement a schedule for checking the temperature precision and pressure accuracy, verifying that the device continues to operate within the specified ranges of 105 to 136 degrees Celsius and 0.1 to 0.23 MPa. Regular maintenance checks should also include verifying the functionality of the sterilization information recording system and the alarm mechanisms. Establishing a proactive maintenance plan ensures the equipment remains a reliable asset, safeguarding patient safety and operational continuity for years to come.

FAQs

What sterilization temperatures does this autoclave support?

This equipment supports sterilization temperatures of 121 and 134 degrees Celsius. It features an automatic operation way with an LCD display for monitoring. The device includes an ultra-high temperature alarm to ensure safety during the heating dry procedure for medical use applications.

Can I customize the specifications of this autoclave?

Yes, customization is available for this pressure steam sterilization equipment. The product originates from Zhengzhou, China, and comes with CE, SGS, and ISO13485 certifications. Buyers can select from various models like HP-AC2N or HP-AC12B depending on their specific chamber volume needs.

Which power supply voltage is required for operation?

The unit operates on 220V or 380V power supply depending on the specific model selected. Some larger capacity versions require 380V at 50Hz. The system includes temperature precision of 0.1 degree and pressure precision of 0.1kpa for accurate medical sterilization cycles.

How is the sterilization information recorded and printed?

The machine features a dedicated sterilization information recording and printing function. It utilizes an LCD display to show working temperature and pressure data. This ensures traceability for medical use while maintaining an ambient temperature range of 5 to 40 degrees Celsius during operation.

What is the maximum working pressure for this device?

The maximum working pressure reaches 0.23MPa for certain models, while others operate at 0.14 MPa. The system includes a water separation feature and an ultra-high temperature alarm. It is designed for middle-aged and old group applications with a stainless steel chamber.

What packaging options are available for shipping?

Packaging options include regular packing or a wooden package depending on the model. The product originates from Zhengzhou, China, and is exported globally. Specific models like HP-HAC150 come with detailed dimensions and weight specifications for safe international transport of the autoclave.

Which certification standards does this equipment meet?

The equipment meets CE, SGS, and ISO13485 certification standards. Some models also carry ISOSGS and ISOCE certifications. These standards ensure the pressure steam sterilization equipment is safe for imaging diagnostic equipment classification and medical use in various global markets.