Source Stackable Medical Syringe Pump for Infusion Therapy
Explore 30 listings of stackable medical syringe pump options featuring LCD displays, adjustable flow rates, and single-channel operation. Buyers can compare specifications, certifications, and pricing to find suitable devices for clinical infusion therapy and insulin adjusting applications.
Key considerations
Products List
Comprehensive Sourcing Guide
Strategic Sourcing Guide for Stackable Medical Syringe Pumps
Understanding the Technical Architecture of Stackable Systems
When sourcing stackable medical syringe pumps, buyers must first distinguish between single-channel and multi-channel configurations that enable vertical stacking. The core technical requirement for a stackable system is the physical and electrical integration of multiple infusion units. Based on observed product attributes, these devices often feature a compact footprint with dimensions such as 280mm in length, 210mm in width, and 130mm in height, allowing for efficient rack mounting or wall installation. The physical design must accommodate the weight of the unit, which typically ranges around 2.2kg, ensuring stability when stacked or mounted in a clinical environment.
A critical technical differentiator in this category is the display interface. Market observations indicate a split between models with LCD displays and those without. For stackable applications in intensive care or operating rooms, units equipped with an LCD display provide superior visibility of infusion rates, volumes, and alarm states without requiring the clinician to look away from the patient. The operational power requirements are generally standardized to AC100~240.0V at 50/60Hz, ensuring global compatibility. However, for mobile or backup scenarios, some models integrate a Lithium Battery with a capacity of 11.1V/2000mAh or a 10.8V system with a 55VA maximum load, which is essential for uninterrupted therapy during power fluctuations.
The precision of the pump mechanism is paramount. High-performance units in this category often boast an accuracy of ±2%, while other models may operate within a ±5% tolerance. The limiting volume range typically spans from 0 to 999.9ml, with the injected volume capability extending up to 9999.9ml, accommodating a wide spectrum of therapeutic needs. The Kvo rate, or flow rate, is a specific parameter where some units are rated at 1ml/H, suitable for delicate pediatric or neonatal infusions. Syringe compatibility is another vital technical specification; the system must support a broad range of syringe sizes, including 2ml, 5ml, 10ml, 20ml, 30ml, and 50/60ml options. Advanced models feature auto-recognition capabilities, automatically detecting the syringe size to adjust the flow rate parameters, thereby reducing the risk of human error during setup.
Compliance and Certification Verification Protocols
Navigating the regulatory landscape for medical devices requires rigorous verification of certifications and standards. Buyers should not assume that all listed products meet specific regulatory requirements without direct confirmation. The supply chain for these devices often references multiple certification bodies. Observed data points to the presence of ISOCE and CE ISO markings, alongside specific certificates such as CE/ISO13485. The ISO13485 standard is particularly significant as it relates to quality management systems specific to medical devices, indicating a manufacturer's commitment to consistent quality control.
Safety classification is another non-negotiable aspect of compliance. The observed products are categorized as Class II safety level devices, which implies a moderate to high risk and necessitates special controls to ensure safety and effectiveness. This classification often dictates the type of electrical safety testing required, such as leakage current and dielectric strength tests. The atmospheric pressure operating range of 860hpa to 1060hpa suggests that these devices are designed to function reliably in various hospital environments, from high-altitude facilities to standard pressure rooms.
Electrical safety is further reinforced by the inclusion of specific fuse specifications. Documentation indicates the use of F1al/250V fuses, with some models featuring two fuses installed inside the pump for redundant protection. This dual-fuse configuration is a critical safety feature that prevents electrical hazards in the event of a surge or internal short circuit. Buyers must verify that the fuse specifications match the local electrical codes of the destination country. Furthermore, the product standard often references specific dimensions like 353116cm for packaging or 280(L)*210(W)*130(H)(mm) for the unit itself, which are essential for logistics planning but must be distinguished from the device's operational standards.
Cost Drivers and Pricing Dynamics
The pricing structure for stackable medical syringe pumps is influenced by a complex interplay of technical specifications, certification levels, and customization options. The observed listed price range in the market spans from 100 to 1600 USD. This wide variance suggests that the cost is heavily dependent on the feature set. A unit priced at the lower end of the spectrum may lack an LCD display, have a lower accuracy rating (±5%), or offer limited battery backup capabilities. Conversely, units at the higher end likely feature high-precision accuracy (±2%), advanced auto-recognition for syringe sizes, and robust battery systems for extended mobile use.
Customization is a significant cost driver in this sector. While standard models are available, the option for custom logos, specific packaging, or tailored technical configurations can increase the unit price. The availability of customization is explicitly noted in product attributes, allowing buyers to brand the device for their specific hospital network or regional distributor requirements. However, this customization often comes with a Minimum Order Quantity (MOQ) constraint. The observed MOQ range is between 1 and 100 units, meaning that small procurement teams may face higher per-unit costs or limited customization options compared to large-scale institutional buyers.
Packaging and logistics also contribute to the total cost of ownership. Products are shipped in various configurations, from neutral packing to standard export packing, with some units packed 100 pieces per carton. The weight of the unit, approximately 2.2kg, and the dimensions of the packaging (e.g., 353116cm) impact shipping costs, particularly for international procurement. Buyers should calculate the total landed cost, including freight, insurance, and potential duties, rather than focusing solely on the base unit price. The warranty period, typically ranging from 12 months to two years, is another factor that influences pricing; extended warranties often command a premium but reduce long-term operational risks.
Typical Clinical Applications and Functional Scope
Stackable medical syringe pumps are designed for a diverse range of clinical applications, primarily centered around precise fluid administration. The theoretical basis for these devices is often categorized under electrotherapeutics, indicating their use in delivering therapeutic agents with high precision. One of the primary functions observed is insulin adjusting, making these pumps essential for diabetes management and critical care where blood glucose levels must be tightly controlled. The ability to deliver low flow rates, such as 1ml/H, is critical for neonatal and pediatric care, where even minor dosing errors can have severe consequences.
The versatility of the syringe size compatibility allows these pumps to be used in various departments, from general wards to intensive care units. The support for syringe sizes ranging from 2ml to 60ml enables the administration of everything from potent vasoactive drugs to larger volume fluid replacements. The single-channel configuration is standard for many models, but the stackable nature of the system allows multiple channels to be deployed in a single footprint, facilitating the simultaneous infusion of multiple medications. This is particularly valuable in emergency medicine and surgery, where patients often require complex drug regimens involving anticoagulants, analgesics, and vasopressors.
The atmospheric pressure tolerance and the inclusion of safety features like Class II electrical protection make these devices suitable for use in a wide variety of hospital settings. The warranty period of 12 months or two years provides a safety net for clinical operations, ensuring that the device remains functional for critical patient care. The inclusion of accessories such as power lines, operating manuals, and warranty cards ensures that the device is ready for immediate deployment upon arrival. The theory of operation, based on electrotherapeutics, underscores the device's role in delivering precise, controlled doses of medication to achieve therapeutic outcomes.
Supplier Evaluation and Quality Control Standards
Evaluating suppliers for stackable medical syringe pumps requires a multi-faceted approach that goes beyond simple price comparison. Buyers should prioritize suppliers who can demonstrate a clear lineage of quality management systems, specifically those certified to ISO13485. This certification is a strong indicator that the manufacturer adheres to international standards for medical device quality. The presence of CE certification and ISOCE markings further validates the product's compliance with European and international safety requirements. However, buyers must verify that these certifications are current and applicable to the specific model being purchased, as certifications can be model-specific.
Quality control processes should be scrutinized to ensure consistency. The observed accuracy ratings of ±2% and ±5% highlight the need for rigorous testing protocols. Buyers should request test reports or quality assurance documentation that verifies these accuracy claims under various operating conditions. The physical construction of the pump, including the fuse specifications and battery integrity, must be consistent across all units. The use of two fuses in some models suggests a design philosophy that prioritizes redundancy and safety, which should be a key criterion in supplier selection.
Packaging and labeling are also indicators of supplier quality. The variation in packaging from neutral to standard export packing, and the specific mention of "Netrual or Customerized" logos, suggests that suppliers have the flexibility to meet different market needs. However, buyers should ensure that the packaging protects the device during transit, especially given the weight and dimensions of the units. The inclusion of a warranty card and operating manual in the package is a basic requirement, but the quality of these documents and the availability of technical support are equally important.
Long-Term Procurement and Operational Considerations
Long-term procurement strategies for stackable medical syringe pumps must account for the total cost of ownership, including maintenance, consumables, and potential downtime. The warranty period, typically 12 months or two years, is a critical factor in this calculation. Buyers should negotiate extended warranty options or service level agreements that cover parts and labor beyond the standard period. The availability of spare parts, such as fuses and batteries, should be confirmed to ensure that the device can be quickly repaired if a failure occurs.
The customization options available, such as logo placement and specific packaging, can be leveraged to build a cohesive brand identity for the hospital or distributor. However, buyers should be aware that customization may impact lead times and minimum order quantities. The observed MOQ range of 1 to 100 units suggests that smaller orders may be more flexible but potentially more expensive per unit. For large-scale deployments, negotiating bulk pricing and extended service contracts can significantly reduce the long-term cost.
The operational environment of the device is another consideration. The atmospheric pressure range of 860hpa to 1060hpa ensures reliability in various settings, but buyers should verify that the device is suitable for their specific location. The power requirements of AC100~240.0V are generally universal, but the inclusion of a battery backup is essential for facilities with unstable power grids. The battery life and charging capabilities should be evaluated to ensure that the device can operate for the required duration during power outages.
In conclusion, sourcing stackable medical syringe pumps requires a balanced approach that considers technical specifications, regulatory compliance, cost drivers, and long-term operational needs. By focusing on high-confidence facts and avoiding unverified claims, buyers can make informed decisions that ensure the safety and efficacy of their medical equipment. The diversity of models available, from those with LCD displays to those with advanced battery systems, provides ample opportunity to select the right device for specific clinical requirements.
FAQs
What certifications do stackable medical syringe pumps hold?
These devices typically hold ISOCE and CE ISO certifications, with some models featuring CE/ISO13485 certificates. Buyers should verify that the specific model matches the required safety standards for their region before procurement.
How accurate are the infusion rates of these pumps?
High-performance units often boast an accuracy of plus-minus 2 percent, while other models operate within a plus-minus 5 percent tolerance. The precision depends on the specific model and its intended clinical application.
Which syringe sizes are compatible with these pumps?
The system supports a broad range of syringe sizes including 2ml, 5ml, 10ml, 20ml, 30ml, and 50/60ml options. Advanced models feature auto-recognition capabilities to automatically detect the syringe size for optimal flow adjustment.
Can these pumps operate on battery power?
Yes, some models integrate a Lithium Battery with a capacity of 11.1V/2000mAh or a 10.8V system with a 55VA maximum load. This feature ensures uninterrupted therapy during power fluctuations or mobile scenarios.
What is the warranty period for these devices?
The warranty period typically ranges from 12 months to two years depending on the specific manufacturer and model. Extended warranties often command a premium but reduce long-term operational risks for clinical buyers.
How much do these pumps weigh?
The physical design accommodates a weight of approximately 2.2kg, ensuring stability when stacked or mounted in a clinical environment. This compact footprint allows for efficient rack mounting or wall installation.
Is customization available for these medical pumps?
Customization is available for logos, specific packaging, and tailored technical configurations to meet specific hospital network requirements. However, this customization often comes with a Minimum Order Quantity constraint ranging from 1 to 100 units.





























