Explore 30 options for a modular iso 5 8 cleanroom tent designed for pharmaceutical, electronics, and laboratory environments. Compare features like HEPA filtration, remote control operation, and customizable sizes to find the right solution for your facility; compare the available evidence and request quotations based on your requirements.

Key considerations

Products List

Comprehensive Sourcing Guide

Modular Iso 5 8 Cleanroom Tent Sourcing Guide

Procuring a modular cleanroom tent requires careful evaluation of the structural frame and wall materials to ensure they meet specific ISO classification requirements. Buyers should verify that the frame utilizes SUS Aluminum or Stainless Steel to provide the necessary rigidity while maintaining a lightweight profile for easy assembly. The wall systems often combine anti-static PVC curtains with sandwich panels or acrylic sheets, offering flexibility for different contamination control needs.

The internal environment must be engineered to support critical applications in the electric, LCD, and TV industries, as well as pharmaceutical manufacturing. Sourcing teams need to confirm that the selected unit includes a dedicated HVAC system capable of managing temperature and humidity alongside air filtration. Ensuring the design software supports custom CAD layouts is essential for integrating the cleanroom into existing facility footprints without disrupting current operations.

Product Scope and Observed Listing Signals

Market listings for these units typically display a wide price range, reflecting the variability in size, cleanliness class, and customization levels. Buyers should expect observed prices to span from low-cost entry points to significant investments for large-scale, high-grade installations. The minimum order quantity often starts at a single unit, allowing for pilot projects, though larger orders may trigger different commercial terms.

Listing signals indicate that these systems are frequently offered with remote control capabilities and specific lighting configurations like LED fixtures. The product scope often includes various floor options, such as PVC flooring, which must be compatible with the intended industrial usage. It is crucial to distinguish between standard models and those with custom designs, as the latter may involve specific lead times and engineering requirements.

Technical Specifications to Verify

Verification of the HEPA filter efficiency is paramount, as the system must consistently achieve 99.99% filtration at 0.3 microns to maintain ISO 5 to ISO 8 standards. Buyers must confirm the FFU quantity and dimensions, typically 1175575320mm, to ensure adequate air changes per hour for the specific room size. The noise level should be checked against operational requirements, with observed ranges often falling between 60 and 70 decibels.

The power supply specifications must align with local grid standards, typically ranging from AC220 to 380 volts at 50Hz. It is essential to validate the fire rating of the sandwich panels and acrylic walls, ensuring they meet the required safety classification for the facility. Additionally, the cleanliness grade should be explicitly defined as ISO5, ISO6, ISO7, or ISO8, depending on the specific process requirements of the client.

Compliance and Safety Documentation

Documentation verification should begin with the qualification documents, which must include IQ, OQ, PQ, and DQ reports to prove system validation. Buyers need to ensure that the supplier provides evidence of certifications such as CE, UL, and GMP, which are critical for pharmaceutical and electronics manufacturing compliance. The absence of these documents can lead to regulatory hurdles during facility audits and operational approvals.

Safety features like fireproof materials and anti-static properties are non-negotiable for protecting both personnel and sensitive equipment. The product standard should be explicitly customized or aligned with specific client requests rather than relying on generic industry defaults. Ensuring that the fire rating is documented as a specific value, such as a rating of 3, helps in meeting local building codes and insurance requirements.

Cost Drivers and Commercial Terms

The primary cost drivers for these modular systems include the frame material, the extent of customization, and the required cleanliness class. Larger square meterages and higher ISO grades naturally increase the price due to the additional FFUs and more complex HVAC integration. Buyers should anticipate that custom designs requiring specific CAD layouts will incur higher engineering and fabrication costs compared to standard configurations.

Commercial terms often involve export wooden cases or specialized export packages to ensure safe transit of the modular components. The minimum order quantity can vary, but suppliers frequently allow for single-unit purchases to facilitate testing before full-scale deployment. It is vital to clarify the lead time and production schedule, as custom requests may extend the delivery window significantly beyond standard inventory items.

Supplier Qualification and Quality Control

Supplier qualification requires a thorough review of their design capabilities, specifically their proficiency with CAD software for creating custom cleanroom layouts. Buyers should assess the supplier's track record in delivering units that meet the specified ISO grades and fire ratings without compromise. The ability to provide detailed qualification documents is a strong indicator of a supplier's commitment to quality and regulatory adherence.

Quality control processes must be transparent, with the supplier demonstrating how they verify the anti-static properties of PVC curtains and acrylic walls. Inspections should cover the structural integrity of the SUS Aluminum or Stainless Steel frames to prevent future deformation or failure. Establishing clear communication channels for addressing any discrepancies in the delivered product is essential for maintaining project timelines and operational readiness.

Long-Term Procurement Checks

Long-term procurement success depends on the availability of spare parts and the ease of maintenance for the HVAC and filtration systems. Buyers should verify that the supplier offers ongoing support for the AHU, ducting, piping, and dehumidifier components to ensure continuous operation. A robust after-sales service plan is necessary to address any potential issues with the FFU units or control systems over the lifespan of the installation.

Regular audits of the cleanroom environment are required to maintain the specified cleanliness class and ensure the HEPA filters remain effective. Procurement teams should establish a schedule for replacing consumables and inspecting the fire rating of the wall panels periodically. Maintaining a relationship with a supplier who understands the specific application needs of the electric, LCD, or pharmaceutical industries will facilitate smoother upgrades and expansions in the future.

FAQs

What certifications are available for modular iso 5 8 cleanroom tent systems?

Certifications such as ISOCE, ISOCCC, CE, UL, and GMP are available for these modular cleanroom systems. These credentials ensure compliance with international quality and safety standards. Buyers can select units based on specific regulatory requirements for their industry, ensuring the facility meets necessary operational benchmarks for cleanroom environments.

How is the cleanliness grade defined for modular iso 5 8 cleanroom tent structures?

The cleanliness grade ranges from ISO5 to ISO8, corresponding to Class 100 to 10,000 standards. This classification depends on the number of Fan Filter Units installed and the total room size. The system allows for precise control over particulate levels, making it suitable for sensitive manufacturing processes requiring strict environmental control.

Can the modular iso 5 8 cleanroom tent be customized for specific industries?

Yes, customization is available to suit industries like pharmaceuticals, electronics, LCD, and TV manufacturing. The design software supports CAD planning, and the modular structure allows for tailored dimensions. Buyers can specify wall materials, flooring, and lighting to match their unique production needs and spatial constraints effectively.

What materials are used for the walls in a modular iso 5 8 cleanroom tent?

Wall options include sandwich panels, anti-static acrylic, and anti-static PVC curtains for soft walls. The frame is constructed from SUS aluminum or stainless steel for durability. These materials provide a clean, static-free environment while maintaining structural integrity, ensuring the cleanroom remains effective for sensitive industrial applications and processes.

What is the typical noise level of a modular iso 5 8 cleanroom tent?

The typical noise level ranges from 60 to 70 decibels. This level is managed through the design of the HVAC system and Fan Filter Units. The system ensures a comfortable working environment while maintaining the necessary air filtration and temperature control required for high-precision manufacturing and pharmaceutical production processes.

Which power supply options are supported by modular iso 5 8 cleanroom tent units?

The units support AC220-380V power supplies at 50Hz frequency. This flexibility allows installation in various global locations with different electrical standards. The power system integrates with the HVAC and lighting components to ensure stable operation, providing reliable performance for continuous industrial use in controlled cleanroom environments.