Source 6 channels infrared fiber analyzer for Grain, Feed, Meat
Find 30 listings for the 6 channels infrared fiber analyzer designed for testing grain, animal feed, and meat samples. Buyers can compare specifications, prices, and delivery times from verified Chinese manufacturers offering ISO9001 certified equipment.
Key considerations
Products List
Comprehensive Sourcing Guide
6 Channels Infrared Fiber Analyzer Sourcing Guide
Selecting the right laboratory equipment for fiber analysis requires a clear understanding of the distinction between traditional digestion methods and modern infrared technologies. While the core keyword suggests an infrared-based solution, current market observations indicate a significant presence of 6-channel crude fiber analyzers that utilize the acid-base digestion method. Buyers must carefully distinguish between these two technological approaches, as they serve different operational needs regarding throughput, accuracy, and chemical usage. The decision to procure a 6-channel system is often driven by the need to process multiple samples simultaneously, thereby increasing laboratory efficiency and reducing per-sample analysis time.
This guide provides evidence-based procurement advice for sourcing 6-channel fiber analyzers, focusing on the specific attributes observed in current listings. It addresses technical verification, compliance requirements, and commercial terms to help buyers make informed decisions. By aligning procurement strategies with the actual specifications of available units, such as the CXC-06, F2000, and NCXC-06 models, buyers can avoid mismatches between expected performance and delivered capabilities. The following sections detail the critical factors that influence the total cost of ownership and operational success of these instruments.
Product Scope and Observed Listing Signals
The current market for 6-channel fiber analyzers shows a diverse range of models, primarily centered around the acid-base digestion method rather than pure infrared spectroscopy. Listings frequently highlight the "6 Channels" feature, which allows for the simultaneous processing of up to six samples, significantly enhancing throughput for high-volume laboratories. These units are typically designed for testing a variety of materials, including grain, animal feed, meat, vegetables, and specific by-products like corn gluten meal. The ability to handle such a wide variety of test items makes these analyzers versatile tools for quality control in food, feed, and agricultural sectors.
Observed product attributes reveal specific operational parameters that define the scope of these instruments. For instance, the weighing sample range is typically between 0.5 to 3 grams, with a test time of approximately 100 minutes per cycle. The measurement range is generally 0 to 100%, providing comprehensive coverage for fiber content analysis. Buyers should note that while some listings mention "infrared" in the keyword, the detailed specifications often point to automated digestion systems. Therefore, it is crucial to verify the actual analysis method, as the acid-base digestion method relies on chemical reagents and thermal processing, which differs fundamentally from non-destructive infrared scanning techniques.
Technical Specifications to Verify
When evaluating technical specifications, buyers must prioritize the power requirements and physical dimensions to ensure compatibility with existing laboratory infrastructure. The observed power supply for these units is consistently AC220V/50Hz, with a rated power consumption around 2800W. This high power draw is necessary to maintain the heating elements required for the digestion process. Additionally, the physical footprint is a critical consideration, with common dimensions measuring 670mm x 450mm x 670mm. Buyers should verify that their laboratory space can accommodate this size and that the electrical circuits can support the 2800W load without overloading.
Water supply conditions are another vital technical aspect that is often overlooked during the initial selection phase. The supplied facts indicate a requirement for water pressure greater than 1.5 MPa and a water temperature below 20 degrees Celsius. These conditions are essential for the cooling and rinsing phases of the digestion cycle. If the laboratory’s water system does not meet these pressure and temperature standards, the analyzer may not function correctly, leading to inconsistent results or equipment damage. Buyers must also check the error margin, which is listed as 0.4% in some models, to ensure the precision meets their quality control standards.
Compliance and Safety Documentation
Compliance with international quality standards is a key indicator of manufacturing reliability. Many of the observed units are associated with ISO9001 certification, which signifies that the manufacturer adheres to a recognized quality management system. Buyers should request proof of this certification and verify that it is current and applicable to the specific model being purchased. While ISO9001 does not guarantee the performance of the individual unit, it provides confidence in the consistency of the manufacturing process and the supplier’s commitment to quality control.
Safety documentation is equally important, particularly given the use of strong acids and bases in the digestion process. Buyers should ensure that the equipment includes adequate safety features, such as automated controls to prevent chemical spills or overheating. The digital display and automation features observed in these units suggest a level of user interaction that minimizes direct exposure to hazardous chemicals. However, buyers must still verify that the supplier provides comprehensive safety manuals and that the equipment design includes necessary ventilation or containment features. The "Cleared" function attribute may refer to safety interlocks or data clearance protocols, which should be clarified with the supplier.
Cost Drivers and Commercial Terms
The price range for 6-channel fiber analyzers is broad, observed between $1 and $27,000 USD, reflecting significant variations in brand, technology, and included features. This wide range indicates that buyers should not rely solely on price as a determinant of quality. Lower-priced units may lack advanced automation, digital displays, or robust build quality, while higher-priced models may offer superior precision, additional channels, or enhanced software integration. Buyers must align their budget with their specific analytical needs, considering whether the 6-channel capacity is necessary for their current and projected workload.
Commercial terms also play a crucial role in the total cost of ownership. The observed payment terms are typically TT (Telegraphic Transfer), and the delivery time is often cited as 5 days after payment. Buyers should verify these terms with the supplier, as lead times can vary based on customization requests or stock availability. Additionally, the packaging is described as a wooden box or carton, meeting export standard requirements. This is important for international shipments, as proper packaging protects the sensitive electronic and mechanical components from damage during transit. Buyers should confirm who bears the risk and cost of shipping and insurance.
Supplier Qualification and Quality Control
Supplier qualification is a critical step in ensuring the reliability of the purchased equipment. Most observed units originate from China (Mainland), with specific mentions of Henan as a production location. Buyers should verify the supplier’s business license and manufacturing capabilities to ensure they are a legitimate producer or authorized distributor. The presence of customization options, such as the "Customized" attribute, suggests that some suppliers can tailor the equipment to specific laboratory requirements. Buyers should assess the supplier’s ability to provide these customizations without compromising the core functionality or warranty of the unit.
Quality control processes should be transparent and verifiable. Buyers should inquire about the testing procedures used before shipment, including calibration and performance checks. The "Grade: Class a" attribute may indicate a quality tier, but buyers should seek detailed information on what this classification entails. Additionally, the brand "Nanbei" is mentioned in some listings, which may be a reputable manufacturer in the laboratory equipment sector. Buyers should research the brand’s reputation and customer feedback to gauge the long-term reliability of their products. Requesting references or case studies from other laboratories using the same model can provide valuable insights into real-world performance.
Long-Term Procurement Checks
Long-term procurement success depends on the availability of spare parts and technical support. Buyers should confirm the supplier’s policy on warranty coverage and the availability of replacement parts, such as heating elements, pumps, and sensors. The complexity of the 6-channel system means that regular maintenance is required to ensure consistent performance. Buyers should ask for a recommended maintenance schedule and the cost of annual service contracts. Understanding the lifecycle of consumables, such as chemical reagents and filters, is also essential for budgeting ongoing operational costs.
Data management and software updates are increasingly important for modern laboratory equipment. Buyers should verify whether the digital display and automation features include data export capabilities, such as USB or network connectivity. This allows for seamless integration with Laboratory Information Management Systems (LIMS). Additionally, buyers should inquire about the supplier’s policy on software updates and firmware upgrades. Ensuring that the equipment can be updated to meet evolving regulatory requirements or to improve functionality will extend the useful life of the investment. Finally, buyers should establish a clear communication channel with the supplier for technical support, ensuring that any issues can be resolved promptly to minimize downtime.
FAQs
What is the analysis method used by the 6 channels infrared fiber analyzer?
The analyzer uses the Acid-Base Digestion Method to determine crude fiber content. This standard laboratory technique involves treating samples with specific acids and bases to isolate the fiber fraction. It is suitable for testing various organic materials including grains, animal feed, meat, and vegetables.
What is the measurement range and sample weight for the 6 channels infrared fiber analyzer?
The device measures crude fiber content within a range of 0 to 100 percent. It requires weighing samples between 0.5 and 3 grams for accurate analysis. The system supports testing 1 to 6 samples simultaneously, allowing for efficient batch processing in laboratory settings.
What are the power requirements for the 6 channels infrared fiber analyzer?
The analyzer requires an AC220V power supply with a frequency of 50Hz. The rated power consumption is 2800W. It also requires a water supply with a pressure greater than 1.5MPa and a temperature below 20 degrees Celsius to operate correctly.
What is the physical size and weight of the 6 channels infrared fiber analyzer?
The unit has dimensions of 670mm by 450mm by 670mm. It weighs approximately 30kg. The product is typically packed in a wooden box or case that meets export standard requirements, ensuring safe transport for international shipping.
What is the test time for the 6 channels infrared fiber analyzer?
The standard test time for a complete analysis cycle is 100 minutes. This duration allows for the full digestion and filtration process required by the acid-base method. The automated performance helps maintain consistency across the six available channels.
What is the accuracy error rate of the 6 channels infrared fiber analyzer?
The analyzer has an error rate of 0.4 percent. This level of precision is suitable for quality control in food and feed industries. The digital display provides clear readouts for the measured crude fiber content in each channel.
What materials can be tested with the 6 channels infrared fiber analyzer?
The device is designed to test organic materials such as grain, animal feed, meat, vegetables, and corn gluten meal. It is applicable for use in industries involving cattle, chicken, dog, fish, horse, and pig feed production. The system supports food quality testing applications.





























