Source Dissolved Oxygen Meter for Lab, Hospital, and School
Source the dissolved oxygen meter from 30 verified listings. Compare models like DOG-2092 and DOG-3082 for features such as 4-20mA output, RS485 communication, and IP68 protection. Evaluate specifications including measuring ranges and temperature compensation to find the right fit for your industrial or laboratory needs.
Key considerations
Products List
Comprehensive Sourcing Guide
Dissolved Oxygen Meter Sourcing Guide
Procuring dissolved oxygen meters requires careful attention to the specific measurement ranges and output signals that align with your operational needs. The market offers units with measuring ranges spanning from 0.00 to 19.99 mg/L or 0 to 100.0 ug/L, alongside saturation capabilities up to 199.9%. Buyers must verify that the selected device supports the required output signal, such as the standard 4-20mA current loop or isolated 0-10mA options, to ensure seamless integration with existing control systems.
Selection also depends heavily on the physical installation constraints and environmental robustness of the instrument. Available models feature compact dimensions like 96x96mm for panel mounting or larger units measuring 146x146mm, with specific hole cutouts required for installation. Furthermore, the protection class, such as IP68, and the operating temperature range of -20 to 60 degrees Celsius are critical factors for ensuring the device functions reliably in harsh industrial or outdoor environments without premature failure.
Product Scope and Observed Listing Signals
The observed product listings indicate a diverse range of dissolved oxygen meters tailored for various industrial and laboratory applications. Models are frequently categorized by their specific model numbers, such as DOG-2092 or DOG-3082, which often dictate the available features like LCD displays, RS485 communication interfaces, and specific power supply requirements ranging from 220V AC to 24V DC. This variety allows buyers to match the instrument's capabilities precisely to their specific workflow, whether for hospital labs, schools, or heavy industrial process control.
Listing signals also reveal significant variation in customization options and packaging standards across different suppliers. Many units offer customizable configurations, including optional power supplies and communication interfaces like RS232 or RS485, while others come standard in carton boxes with defined packing dimensions. Buyers should scrutinize these signals to confirm that the specific unit they intend to purchase includes the necessary accessories and meets the exact dimensional and functional requirements of their facility before finalizing any order.
Technical Specifications to Verify
Accuracy and resolution are paramount when selecting a dissolved oxygen meter for precise process monitoring. The observed data highlights units with an accuracy of ±1.5% F.S. and resolutions as fine as 0.01 mg/L or 0.1 ug/L, depending on the selected range. Procurement teams must verify that the specific model's resolution matches the sensitivity required for their application, as lower resolution units may fail to detect subtle changes in oxygen levels that are critical for maintaining water quality standards or biological process efficiency.
Response time and temperature compensation capabilities are equally vital for ensuring real-time data reliability in dynamic environments. Devices typically feature a response time of less than 60 seconds and include automatic temperature compensation ranging from 0 to 60 degrees Celsius to correct readings based on thermal variations. Buyers should confirm that the selected meter includes these compensation features and that the clock accuracy, often specified as ±1 minute per month, is sufficient for long-term data logging and audit trail requirements without frequent manual recalibration.
Compliance and Safety Documentation
Safety and regulatory compliance are non-negotiable when sourcing industrial instrumentation that interacts with critical processes. The available product data indicates that many units carry certifications such as RoHS, ISO, and CE, which are essential for ensuring the device meets international safety and environmental standards. Procurement professionals must request and verify these specific certification documents for each batch of equipment to guarantee that the meters do not contain hazardous substances and adhere to the electrical safety norms required in their region.
Electrical safety and relay load specifications must also be rigorously checked to prevent system failures or hazards during operation. The observed listings specify relay loads capable of handling AC 230V at 5A or AC 220V at 3A for alarm functions, which dictates the maximum power the device can switch safely. Buyers should ensure that the relay ratings of the purchased unit exceed the load requirements of their connected alarms or control circuits to avoid relay contact welding or failure, which could lead to dangerous operational blind spots.
Cost Drivers and Commercial Terms
Pricing for dissolved oxygen meters varies significantly based on the complexity of the specifications and the level of customization required. The observed market shows a wide price range from 1 to 3000 USD, driven by factors such as the inclusion of advanced communication interfaces, higher accuracy ratings, and specialized power supply options. Buyers should analyze the total cost of ownership rather than just the unit price, considering that higher-end models with RS485 interfaces and data storage capabilities may offer better long-term value through reduced maintenance and improved data integration.
Minimum Order Quantities (MOQ) and lead times are critical commercial terms that influence procurement planning and inventory management. Current listings suggest an MOQ range of 1 to 5 units, offering flexibility for small-scale projects or pilot testing, while larger orders may benefit from negotiated terms. Procurement teams must clarify these terms early in the negotiation process to avoid delays, ensuring that the supplier can meet the required delivery schedule without compromising on the quality or specific configuration of the ordered instruments.
Supplier Qualification and Quality Control
Supplier qualification should focus on the manufacturer's ability to provide consistent quality and technical support for specialized instrumentation. The product origin is listed as China (Mainland), and buyers should verify the supplier's track record in producing meters with the specific model numbers and standards observed in the market. It is essential to confirm that the supplier has established quality control processes that align with the ISO certifications mentioned, ensuring that every unit shipped meets the rigorous performance standards required for industrial applications.
Quality control checks must extend to the physical dimensions and assembly of the devices to ensure compatibility with existing infrastructure. The observed specifications include precise dimensions like 96x96x115mm and hole sizes of 92x92mm, which must be strictly adhered to for proper panel installation. Buyers should request sample units or detailed dimensional drawings to verify that the physical construction matches the listed standards, preventing costly retrofitting or installation failures once the equipment arrives at the facility.
Long-Term Procurement Checks
Long-term procurement success relies on verifying the durability and maintenance requirements of the dissolved oxygen meters over their operational lifespan. Buyers should investigate the expected lifespan of the sensors and the availability of replacement parts, as the measuring range and resolution capabilities can degrade over time without proper maintenance. Ensuring that the supplier offers a clear maintenance schedule and readily available consumables is crucial for maintaining the accuracy and reliability of the dissolved oxygen measurements in continuous operation.
Data storage and communication reliability are key factors for long-term operational efficiency and regulatory compliance. The observed data points to data storage capacities measured in months with specific logging intervals, such as one point every five minutes, which supports detailed historical analysis. Procurement teams must verify that the communication interfaces, including RS485 or optional RS232, remain stable over time and that the data storage capacity is sufficient to meet the facility's record-keeping requirements without the need for frequent manual data extraction or system resets.
FAQs
What are the measuring ranges for dissolved oxygen?
The device supports multiple measuring ranges including 0.00 to 19.99 mg/L and 0 to 100.0 ug/L. It also covers saturation levels from 0.0 to 199.9%. These ranges allow precise monitoring across various water quality conditions. The resolution is 0.01 mg/L or 0.1 ug/L depending on the selected scale. This flexibility ensures accurate readings for both low and high concentration environments.
Can the dissolved oxygen meter be customized?
Yes, customization is available for this instrument. Buyers can request specific configurations to meet unique operational requirements. The product supports various output signals such as 4-20mA and isolated outputs. Communication interfaces like RS485 are also offered. This adaptability allows integration into diverse industrial and laboratory systems without compatibility issues.
What certifications does the dissolved oxygen meter have?
The meter holds RoHS, ISO, and CE certifications. These standards confirm compliance with international safety and environmental regulations. The CE mark indicates conformity with health, safety, and environmental protection standards. RoHS certification ensures restricted hazardous substances are not used. ISO certification verifies adherence to quality management systems for reliable manufacturing processes.
How is the power supply configured for this meter?
The standard power supply is AC 220V plus or minus 10% at 50 plus or minus 1Hz. A 24VDC option is also available for specific applications. The power consumption is less than or equal to 10W. This dual supply flexibility allows installation in various electrical environments. It ensures stable operation for continuous monitoring tasks in different settings.
What is the accuracy and resolution of the device?
The accuracy is plus or minus 1.5% of full scale. The resolution is 0.01 mg/L for concentration and 0.01% for saturation. Temperature compensation operates within 0 to 60 degrees Celsius. This precision ensures reliable data collection for critical applications. The high resolution allows detection of minor changes in dissolved oxygen levels.
What are the dimensions and installation requirements?
The dimensions are 96 by 96 by 115mm with a hole size of 92 by 92mm. Another model measures 146 by 146 by 108mm. The protection class is IP68 for water resistance. Installation is straightforward with standard panel mounting. These compact sizes fit easily into control panels. The robust design ensures durability in harsh industrial environments.