Source Wall Type Medical Oxygen Flowmeter with Humidifier for Hospitals, Clinics, and Home Care
Explore 30 listings for the wall type medical oxygen flowmeter with humidifier designed for hospitals, clinics, and home care settings. Buyers can compare specifications like flow rates, connection types, and sterilization methods to find suitable medical equipment.
Key considerations
Products List
Comprehensive Sourcing Guide
Strategic Sourcing Guide for Wall-Mounted Medical Oxygen Flowmeters with Humidifiers
Procuring wall-type medical oxygen flowmeters equipped with humidifiers requires a rigorous understanding of technical specifications, regulatory compliance, and supply chain reliability. These devices are critical components in respiratory therapy, ensuring patients receive precise oxygen concentrations while maintaining adequate humidity levels to prevent mucosal irritation. The following guide synthesizes available product attributes and industry standards to assist procurement professionals in evaluating potential suppliers and selecting equipment that meets clinical and operational requirements.
Technical Specifications and Functional Attributes
The core functionality of a wall-mounted oxygen flowmeter relies on accurate flow regulation and the integration of a humidification system. Based on observed product data, these units typically feature a flow range capable of delivering between 0 to 15 liters per minute (lpm) or extending up to 0 to 30 lpm, depending on the specific model configuration. The flow measurement mechanism is frequently identified as a float-type or tube-style system, utilizing electrical principles for measurement in certain advanced variants. Accuracy is a paramount specification, with high-performance units claiming an accuracy of ≤±0.1%.
The physical connection interfaces are standardized to ensure compatibility with hospital infrastructure. Inlet connections are commonly specified as G5/8 or CGA540, while outlet connections often utilize a 9/16-18unf thread. The working pressure for these systems can reach up to 15MPa, with outlet pressure regulated between 0.2 and 0.3MPa. A critical feature for wall-mounted units is the inclusion of a humidifier. Observed specifications indicate a reusable humidifier capacity of 170ml, designed specifically for oxygen breathing applications. The device is intended for use with oxygen tanks or cylinders, serving as a bridge between the gas source and the patient.
Some models are classified as "Breathing Apparatus" or "Probe Type Flow Meters," suggesting versatility in application environments. The measuring object is typically a closed pipeline, and the sensor type may vary between tube and flange configurations. Visual indicators are another consideration; while some units feature LCD displays, many standard models are supplied without an LCD display, relying instead on mechanical float indicators. The color of the device is often customizable, allowing facilities to match existing medical equipment aesthetics.
Regulatory Compliance and Certification Verification
Navigating the regulatory landscape is essential for medical device procurement. The supplied data indicates that products in this category frequently hold certifications such as FDA, ISO, CE, GB, DIN, and JIS. Specific certification codes observed include "ISOCE" and "ISOEEC," alongside broader listings like "ISO, CE, GB, DIN, JIS." These certifications suggest adherence to international quality management systems and safety standards.
For medical devices, the regulatory type is a critical classification. The observed data lists these products as "Type 1" Medical Devices, which generally implies a lower risk category but still requires strict adherence to manufacturing and quality standards. Ethical and safety protocols are further reinforced by the mention of Ethylene Oxide Sterilization, indicating that the products are supplied in a sterile condition suitable for direct patient contact.
Buyers must verify that the "Universal" standard mentioned in product attributes aligns with local jurisdictional requirements. While "MALE G5/8 Connection" is listed as a standard, this refers to a mechanical interface standard rather than a regulatory one. It is imperative to confirm that the supplier can provide valid, current certificates for FDA, ISO, and CE, rather than relying solely on marketing claims. The presence of ISO13485 is a background standard often associated with medical devices, though its specific application status should be verified against the actual product documentation provided by the manufacturer.
Cost Drivers and Pricing Dynamics
The pricing for wall-mounted oxygen flowmeters with humidifiers varies significantly based on the complexity of the unit, the inclusion of advanced features, and the volume of purchase. The observed price range for these products spans from 1 to 159 USD. This wide disparity suggests that the market includes both basic mechanical units and more sophisticated models with enhanced features or premium branding.
Several factors influence the final cost. First, the material composition, predominantly plastic, is a baseline cost driver, but the quality of the plastic and the precision of the internal components affect the price. Second, the level of customization plays a major role. Attributes such as "Customization: Available" and "Customized: Customized" indicate that buyers can request specific logos, colors, or connection types, which typically incurs a premium. The "Without Logo Printing" option suggests a base price for standard units, while custom branding adds to the cost.
Minimum Order Quantity (MOQ) is another critical cost determinant. The observed MOQ range is 1 to 300 units. Purchasing at the lower end of this spectrum (MOQ 1) may result in a higher unit price due to the lack of economies of scale. Conversely, ordering at the higher end (up to 300 units) may unlock significant cost savings per unit. Packaging also impacts logistics costs; options range from "Color Box" for individual retail or hospital ward use to "Export Standard Ctns" or "20PCS/CTN" for bulk shipping. Buyers should calculate the total landed cost, including packaging and shipping, rather than focusing solely on the unit price.
Typical Applications and Clinical Use Cases
Wall-mounted oxygen flowmeters with humidifiers are primarily designed for clinical environments where continuous and reliable oxygen delivery is necessary. The "Usage" attribute explicitly states compatibility with "Oxygen Tanks/Cylinders," making these units suitable for hospitals, clinics, and long-term care facilities. The "Group" attribute identifies the target demographic as "Adult," indicating that these specific models are calibrated for adult respiratory needs.
The inclusion of a 170ml reusable humidifier is specifically for "Oxygen Breathing," addressing the issue of dry gas delivery which can cause discomfort and tissue damage in patients receiving high-flow oxygen. This makes the equipment ideal for post-operative care, chronic respiratory disease management, and emergency room settings. The "Application" attribute lists "Transportation," which may imply that these units are robust enough for use in ambulances or mobile medical units, although the "Wall Type" designation suggests a fixed installation is the primary use case.
The "Purpose" is clearly defined as "for Oxygen Breathing," confirming the device's role in therapeutic gas delivery. The "Item Name" often includes descriptors like "Medical High Quality Tube-Flow Regulator," highlighting the dual function of flow regulation and pressure management. These devices are essential for ensuring that the oxygen delivered is not only at the correct flow rate but also at the correct pressure to prevent barotrauma while maintaining patient comfort through humidification.
Supplier Evaluation and Quality Assurance
When evaluating suppliers for medical oxygen flowmeters, buyers must look beyond the basic product listing. The "prod_origin" is consistently listed as "China," with specific mentions of "Ningbo, China" as a manufacturing hub. This geographic concentration suggests a mature supply chain but requires due diligence regarding the specific factory's capabilities.
Quality control should focus on the verification of the "Standard" and "Certification" claims. Buyers should request batch-specific test reports to confirm that the "Accuracy" of ≤±0.1% is maintained across production runs. The "Measuring Principle" of "Electrical Principles" in some models requires validation of the sensor reliability, particularly the "Tube/Flange" sensor types.
The "prod_packing" attributes, such as "Color Box," "Export Standard Ctns," and "Packed in Ctns," provide insight into the supplier's attention to detail. Consistent and robust packaging is vital for preventing damage during transit, especially for precision instruments. Suppliers offering "20PCS/CTN" packing demonstrate an understanding of bulk logistics, which is beneficial for large institutional buyers.
Furthermore, the "Feature" of "Float-Type, Tube-Style" should be inspected for durability and readability. The "Scale" is described as "Small," which may refer to the physical footprint of the device, making it suitable for wall mounting in space-constrained areas. Buyers should verify that the "Inlet Pressure" of 50psi and "Outlet Pressure" of 0.2-0.3MPa are consistent with the facility's gas supply infrastructure.
Long-Term Procurement and Maintenance Considerations
Sourcing medical equipment involves considering the total cost of ownership, including maintenance and replacement cycles. The "Reusable" nature of the 170ml humidifier is a significant long-term advantage, reducing the need for frequent consumable replacements. However, the "Ethylene Oxide Sterilization" status implies that the device may require re-sterilization or replacement if the seal is compromised or after a specific usage period.
The "Customization" options, including "Logo Printing" and "Color" customization, offer branding opportunities but may complicate long-term maintenance if the supply chain for custom parts is disrupted. Buyers should ensure that the supplier can provide spare parts, such as replacement flow tubes or humidifier chambers, for an extended period.
The "Model" numbers, such as "HQ-FM-30L," "HQ-FM-01," and "XF-A3012," serve as unique identifiers for inventory management. Standardizing on specific models can streamline procurement and maintenance processes. The "Universal" standard mentioned in the attributes suggests broad compatibility, but buyers should verify that the "MALE G5/8 Connection" and other interface standards remain consistent with existing hospital infrastructure to avoid costly retrofitting.
Finally, the "Type 1" regulatory classification implies a lower risk profile, but regular calibration and inspection are still necessary to maintain accuracy. Buyers should establish a protocol for periodic verification of the flowmeter's accuracy against a known standard, ensuring that the "≤±0.1%" specification remains valid throughout the device's lifecycle.
Comparative Analysis of Product Variants
To assist in decision-making, the following table summarizes key differences observed among the product attributes, helping buyers distinguish between basic and advanced models.
| Feature | Basic Model Attributes | Advanced/Custom Model Attributes |
|---|---|---|
| Flow Range | 0-15 lpm | 0-30 lpm |
| Display | Without LCD Display | LCD Display (Optional) |
| Logo | Without Logo Printing | Customized Logo Printing |
| Color | Standard | To Be Customized |
| Packing | Color Box / Standard Export | Export Standard Ctns (20PCS/CTN) |
| Certification | ISOCE, FDA | ISO, CE, GB, DIN, JIS |
| Model Series | flowmeter, HQ-FM-01 | HQ-FM-30L, XF-A3012 |
| Sensor Type | Tube/Flange | Probe Type |
This comparison highlights that while the core function remains the same, the level of customization, flow capacity, and regulatory breadth varies significantly. Procurement teams should align their selection with their specific clinical needs, budget constraints, and regulatory environment. By carefully evaluating these attributes, buyers can secure high-quality wall-mounted oxygen flowmeters that ensure patient safety and operational efficiency.
FAQs
What certifications do these flowmeters typically hold?
These units frequently hold FDA, ISO, and CE certifications. Some listings also include GB, DIN, and JIS standards, ensuring compliance with international safety and quality management systems for medical devices.
Can I customize the color and logo on the device?
Yes, customization is available for both color and logo printing. While some standard models come without logo printing, buyers can request specific colors and branding to match facility aesthetics.
What is the flow range for adult oxygen breathing?
The flow range typically spans from 0 to 15 liters per minute or extends up to 0 to 30 liters per minute. These ranges are designed specifically for adult respiratory needs in clinical settings.
How is the humidifier designed for reuse?
The device includes a 170ml reusable humidifier designed for oxygen breathing applications. This feature helps maintain adequate humidity levels to prevent mucosal irritation during continuous oxygen therapy.
What connection standards are used for inlet and outlet?
Inlet connections commonly use G5/8 or CGA540 standards, while outlets often utilize a 9/16-18unf thread. These interfaces ensure compatibility with standard hospital gas supply infrastructure.
Are these devices sterile upon delivery?
Yes, the products are supplied with Ethylene Oxide Sterilization. This ensures the medical devices are in a sterile condition suitable for direct patient contact and clinical use.
What is the minimum order quantity for purchasing?
The minimum order quantity ranges from 1 to 300 units depending on the supplier and model. Lower quantities may result in higher unit prices, while bulk orders can unlock cost savings.